Personlized Products 2014 Pcb Dehumidifier Rotary Switches - ZJEN SERIES VOC Abatement System – Dry Air

Short Description:

Product advantages of VOC Concentrating rotor+Molecular Sieve rotor system: 1. Processing efficiency of molecular sieve rotor is up to 95% and life span is up to 10 years. 2. High economic efficiency:high purity of the recovery solvent and it can be directly used in the production, 3.High safety, it can make up the deficiency of explosiveness of RTO equipment and in flammabilityof active carbon filter unit at high temperature. High concentration exhaust:Deep condensation+RTO(Regenerative ...


Product Detail

Product Tags

Related Video

Feedback (2)

The consumer fulfillment is our primary goal. We uphold a consistent level of professionalism, top quality, credibility and service for New Home Dehumidifier, Popular Industrial Dehumidifier, Lowest Noise Dehumidifier, We welcome new and outdated shoppers from all walks of lifetime to call us for long term company associations and mutual accomplishment!
Personlized Products 2014 Pcb Dehumidifier Rotary Switches - ZJEN SERIES VOC Abatement System – Dry Air Detail:

1

Product advantages of VOC Concentrating rotor+Molecular Sieve rotor system

1. Processing efficiency of molecular sieve rotor is up to 95% and life span is up to 10 years.

2. High economic efficiency:high purity of the recovery solvent and it can be directly used in the production,

3.High safety, it can make up the deficiency of explosiveness of RTO equipment and in flammabilityof active carbon filter unit at high temperature.

2

High concentration exhaust:Deep condensation+RTO(Regenerative Thermal Oxidizer)/CO 

Working Principle

3

High concentration exhaust is deeply cooled down to -20℃ to -75℃so that the organic waste gas is condensed into a liquid state and recycled. The pollutant in VOC laden air stream is destroyed and converted into carbon dioxide, heat and water at 800  by a RTO burner to meet emission standards. 

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(t)

Rated power

(kw)

Recovery rate(%)

JEN-RH-200-L35E

100-300

5*3.2*3.2

10-15

15

≥95

JEN-RH-400-L35E

300-500

7*3.2*3.2

15-20

30

≥95

JEN-RH-600-L35E

500-700

10*3.2*3.2

25-30

45

≥95

JEN-RH-800-L35E

700-900

10*3.2*3.3

25-30

60

≥95

Note

  1. Discharge to meet local VOC emission standards
  2. Reactivation source is steam,required steam pressure is 0.6Mpa

Large volume, low concentration exhaust: VOC Concentrating rotor+Molecular Sieve rotor

 

Working Principle :

 Large volume, low concentration exhaust   is cooled down by pre-cooler and further processed by a VOC concentrating rotor.The purified air is discharged to the atmosphere through a main exhaust fan.

The moisture in the concentrated and desorbed exhaust gas is removed by cooling coils and a molecular sieve rotor, the temperature of  the exhaust air is cooled down by a heat exchanger and condenser. The condensed air directed to the low-temperature side and recycled as reactivation air of the molecular sieve rotor.

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(t)

Installed power

(kw)

Removal rate

(%)

ZJEN-H-8000-L35E

7000-9000

6*6*4

10

75

≥97

ZJEN-H-15000-L35E

14000-16000

8*8*4

11

100

≥97

ZJEN-H-20000-L35E

18000-22000

8*8*4

12

150

≥97

ZJEN-H-25000-L35E

23000-27000

12*9*6

13

180

≥97

ZJEN-H-30000-L35E

28000-32000

13*9*6

14

225

≥97

ZJEN-H-40000-L35E

38000-43000

14*10*6

15

300

≥97

ZJEN-H-50000-L35E

48000-52000

14*10*6

16

375

≥97

Note

  1. Discharge to meet the local VOC emission standards
  2. Reactivation source is steam,required steam pressure is 0.6Mpa

Large volume, medium concentration exhaust :Active Carbon filter+VOC Concentrating rotor

Principle introduction:

Exhaust gas with concentration of 2200mg/m3 is processed by GAC activated carbon filter device and a zeolite VOC adsorption rotor where it purified to  70mg/m3.

The solvent in the activated carbon filter device is condensed and recycled.

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(ton)

Rated power

(kw)

Moisture content

(%)

ZJEN-H-10000-E

6000-15000

7*7*4

20

50

≤1

ZJEN-H-20000-E

16000-25000

9*9*4

22

100

≤1

ZJEN-H-30000-E

26000-35000

10*8*4

24

150

≤1

ZJEN-H-40000-E

36000-45000

10*8*4

26

200

≤1

Remark

1.Emission concentration ≤ 70mg / m3 to meet local emission standards2.Reactivation source is 180℃ heat conduction oil.

 


Product detail pictures:

Personlized Products 2014 Pcb Dehumidifier Rotary Switches - ZJEN SERIES VOC Abatement System – Dry Air detail pictures


Related Product Guide:
working principle of dehumidifier
How to Choose a Dehumidifier

Assume full obligation to meet all demands of our customers; accomplish ongoing advancements by promoting the advancement of our customers; become the final permanent cooperative partner of clientele and maximize the interests of shoppers for Personlized Products 2014 Pcb Dehumidifier Rotary Switches - ZJEN SERIES VOC Abatement System – Dry Air, The product will supply to all over the world, such as: Argentina, United Arab Emirates, Portland, Customer satisfaction is our first goal. Our mission is to pursue the superlative quality, making continual progress. We sincerely welcome you to make progress hand in hand with us, and construct a prosperous future together.
  • The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
    5 Stars By Rachel from Gabon - 2018.06.03 10:17
    The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Dorothy from Colombia - 2017.08.21 14:13
    
    WhatsApp Online Chat !