Special Design for Domestic Dehumidifier - ZJEN SERIES VOC Abatement System – Dry Air

Short Description:

Product advantages of VOC Concentrating rotor+Molecular Sieve rotor system: 1. Processing efficiency of molecular sieve rotor is up to 95% and life span is up to 10 years. 2. High economic efficiency:high purity of the recovery solvent and it can be directly used in the production, 3.High safety, it can make up the deficiency of explosiveness of RTO equipment and in flammabilityof active carbon filter unit at high temperature. High concentration exhaust:Deep condensation+RTO(Regenerative ...


Product Detail

Product Tags

Related Video

Feedback (2)

Like a result of ours specialty and repair consciousness, our enterprise has won a superb popularity amid buyers everywhere in the environment for Mini Dehumidifiers, Home Supplies Interior Dehumidifier, Dehumidifier Kiln, We acquire high-quality as the foundation of our results. Thus, we focus over the manufacture on the finest top quality goods. A strict quality management system has been created to guarantee the caliber of the merchandise.
Special Design for Domestic Dehumidifier - ZJEN SERIES VOC Abatement System – Dry Air Detail:

1

Product advantages of VOC Concentrating rotor+Molecular Sieve rotor system

1. Processing efficiency of molecular sieve rotor is up to 95% and life span is up to 10 years.

2. High economic efficiency:high purity of the recovery solvent and it can be directly used in the production,

3.High safety, it can make up the deficiency of explosiveness of RTO equipment and in flammabilityof active carbon filter unit at high temperature.

2

High concentration exhaust:Deep condensation+RTO(Regenerative Thermal Oxidizer)/CO 

Working Principle

3

High concentration exhaust is deeply cooled down to -20℃ to -75℃so that the organic waste gas is condensed into a liquid state and recycled. The pollutant in VOC laden air stream is destroyed and converted into carbon dioxide, heat and water at 800  by a RTO burner to meet emission standards. 

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(t)

Rated power

(kw)

Recovery rate(%)

JEN-RH-200-L35E

100-300

5*3.2*3.2

10-15

15

≥95

JEN-RH-400-L35E

300-500

7*3.2*3.2

15-20

30

≥95

JEN-RH-600-L35E

500-700

10*3.2*3.2

25-30

45

≥95

JEN-RH-800-L35E

700-900

10*3.2*3.3

25-30

60

≥95

Note

  1. Discharge to meet local VOC emission standards
  2. Reactivation source is steam,required steam pressure is 0.6Mpa

Large volume, low concentration exhaust: VOC Concentrating rotor+Molecular Sieve rotor

 

Working Principle :

 Large volume, low concentration exhaust   is cooled down by pre-cooler and further processed by a VOC concentrating rotor.The purified air is discharged to the atmosphere through a main exhaust fan.

The moisture in the concentrated and desorbed exhaust gas is removed by cooling coils and a molecular sieve rotor, the temperature of  the exhaust air is cooled down by a heat exchanger and condenser. The condensed air directed to the low-temperature side and recycled as reactivation air of the molecular sieve rotor.

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(t)

Installed power

(kw)

Removal rate

(%)

ZJEN-H-8000-L35E

7000-9000

6*6*4

10

75

≥97

ZJEN-H-15000-L35E

14000-16000

8*8*4

11

100

≥97

ZJEN-H-20000-L35E

18000-22000

8*8*4

12

150

≥97

ZJEN-H-25000-L35E

23000-27000

12*9*6

13

180

≥97

ZJEN-H-30000-L35E

28000-32000

13*9*6

14

225

≥97

ZJEN-H-40000-L35E

38000-43000

14*10*6

15

300

≥97

ZJEN-H-50000-L35E

48000-52000

14*10*6

16

375

≥97

Note

  1. Discharge to meet the local VOC emission standards
  2. Reactivation source is steam,required steam pressure is 0.6Mpa

Large volume, medium concentration exhaust :Active Carbon filter+VOC Concentrating rotor

Principle introduction:

Exhaust gas with concentration of 2200mg/m3 is processed by GAC activated carbon filter device and a zeolite VOC adsorption rotor where it purified to  70mg/m3.

The solvent in the activated carbon filter device is condensed and recycled.

 

Model

Handling capacity

(m3)

Dimensions

(m)

Net weight

(ton)

Rated power

(kw)

Moisture content

(%)

ZJEN-H-10000-E

6000-15000

7*7*4

20

50

≤1

ZJEN-H-20000-E

16000-25000

9*9*4

22

100

≤1

ZJEN-H-30000-E

26000-35000

10*8*4

24

150

≤1

ZJEN-H-40000-E

36000-45000

10*8*4

26

200

≤1

Remark

1.Emission concentration ≤ 70mg / m3 to meet local emission standards2.Reactivation source is 180℃ heat conduction oil.

 


Product detail pictures:

Special Design for Domestic Dehumidifier - ZJEN SERIES VOC Abatement System – Dry Air detail pictures


Related Product Guide:
working principle of dehumidifier
Eva Dry EDV 1100 Electric Petite Dehumidifier Product Overview

We emphasize progress and introduce new solutions into the market each year for Special Design for Domestic Dehumidifier - ZJEN SERIES VOC Abatement System – Dry Air, The product will supply to all over the world, such as: Mexico, Austria, Paraguay, We aim to become the modern enterprise with the commercial ideal of "Sincerity and confidence" and with the aim of "Offering customers the most sincere services and best quality products". We sincerely ask for your unchanged support and appreciate your kind advice and guidance.
  • Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Kim from Congo - 2017.10.27 12:12
    The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Mandy from Palestine - 2017.03.28 16:34
    
    WhatsApp Online Chat !